ASTM D2837及ISO9080热塑性管道材料静水压测试
作者:admin    发布于:2021-08-24 10:16:34    文字:【】【】【
摘要:ASTM D2837及ISO9080热塑性管道材料静水压测试,Testing to ISO 9080 (MRS) and ASTM D2837 (HDB),ASTM D2837 获得热塑性管道材料静水压设计基数或热塑性管道制品用压力设计基数的试验,咨询电话:025-86583475

ASTM D2837 获得热塑性管道材料静水压设计基数或热塑性管道制品用压力设计基数的试验
ASTM D2837 Standard Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials or Pressure Design Basis for Thermoplastic Pipe Products

Testing to ISO 9080 (MRS) and ASTM D2837 (HDB)
A complete evaluation includes hydrostatic pressure testing for generation of test data followed by regression analysis for determination of the long term hydrostatic strength, and finally classification of HDB (Hydrostatic Design Basis) or MRS (Minimum Required Strength).

Pipe materials
Smart has performed more than 300 different evaluations according to ASTM D2837 and/or ISO 9080, covering
PE/PP/PB/PEX/PE-RT/PVC/PSu/PA

ASTM D2837管道压力等级计算方法

ASTM D2837标准压力等级计算方法使用了一个叫做HDB(静液压设计基数)的长期强度值来计算管道压力等级。HDB是根据ASTM D2837 PE管道样品静液压试验得到的试验数据。然后管道工程师根据给出的HDB值使用下面的公式计算给水用PE管道压力等级。

ISO 9080标准压力等级计算方法

ISO标准压力等级计算方法使用了一个叫做MRS(最小要求强度值)的长期强度值来计算管道压力等级。MRS是根据ISO 9080PE管道样品静液压试验得到的试验数据。MRS试验数据提交静液压管理委员会(HSB),PPI的一个独立分支机构。然后它再将MRS值交给PE管道制造商。这些MRS值可从PPI TR-4上查找。

然后管道工程师根据给出的MRS值使用下面的公式计算给水用PE管道压力等级。

聚乙烯管材料的ISO9080等级检测方法 http://www.firete.com/news/zhengce/9398.html
ISO 9080管材静液压强度测试 http://www.fire-test.com/newscenter/regulation/8435.html

更多关于ASTM D2837及ISO9080管道水压测试详细内容,请咨询南京睿督公司
南京睿督公司咨询电话:025-8658 3475  400-603-6575
网址:www.fire-test.com
邮箱:info@fire-test.com


图片
版权所有 Copyright(C)2012-2015 南京睿督科技有限公司 苏公网安备 32010502010102号 苏ICP备12030029号-5
电话:025-8658 3475  传真:025-8658 3457  网址:http://www.en45545-2.com/   邮箱:info@fire-test.com